For most homes with a condensing combi boiler, 60°C is a good setting for the heating. Many combis are left at 70°C to 80°C from the day they're fitted, which is hotter than they need to run well. Turning the heating setting down to 60°C usually means a lower gas bill and a house that feels much the same.

This post explains the two temperature settings on a combi, why a lower heating setting saves gas, how to change it, and when to leave it to an engineer. You only need the dial or buttons on the front of the boiler. Never remove the boiler's casing or touch anything inside it.

The two temperatures on your combi boiler

A combi boiler, short for combination boiler, heats your radiators and your tap water from one unit, with no hot water tank. It has two separate temperature settings, usually marked with symbols on the front:

  • The radiator symbol is the flow temperature. That's how hot the boiler heats the water before it's pumped round your radiators.

  • The tap symbol is the hot water temperature. That's how hot the water is when it comes out of your taps and shower.

Neither is the same as the room thermostat on your wall. The thermostat sets how warm you want the room. The flow temperature sets how hot the radiators run while the heating gets the room there.

Why 60°C saves gas

Boilers fitted in the UK since 2005 have had to be condensing boilers. A condensing boiler recovers extra heat from its exhaust gases, but only when the water coming back from the radiators is cool enough, below about 54°C. When the radiators run very hot, the returning water is too warm to do this, and more heat goes out of the flue.

Running the radiators cooler keeps the boiler condensing for more of the time. Tests at the University of Salford's Energy House, carried out for the innovation charity Nesta, found that turning the flow temperature down from 80°C to 60°C cut a home's total gas use by about 9%. A very hot setting also makes the boiler switch on and off more often, which adds wear to its parts.

Will the house still feel warm?

In most homes, yes. In the same tests, the house took about 17 minutes longer to warm up at 60°C, and was on average about half a degree cooler. The radiators will feel warm rather than too hot to touch, and that's normal.

If rooms take longer to warm up, set the heating to come on 15 to 30 minutes earlier. If it still isn't warm enough, turn the flow temperature up by 5°C and try again. Many homes run happily at 55°C or a little lower, but you may need to turn it back up during a cold snap.

If anyone at home is elderly, unwell or needs to be kept especially warm, start a little higher than 60°C and make sure someone knows how to turn it back up.

How to change the setting safely

  1. Check you have a combi. If there's a hot water cylinder in an airing cupboard, you don't. See the next section.

  2. Find the radiator symbol on the front of the boiler. It may be a dial, or buttons with a small display. Some sit behind a drop-down flap, which is fine to open.

  3. Set it to 60°C. On a dial with no numbers, your boiler's manual will show which mark matches which temperature.

  4. Leave the tap setting where it is for now, or set it so the water is comfortable at the tap.

  5. Give it a few days of normal use before deciding whether to adjust it again.

If you're not sure which control does what, check the manual for your model before pressing anything. The charity Nesta's free Money Saving Boiler Challenge tool also walks you through the most common boiler displays. Whatever you change, you can always change it back.

If you have a hot water cylinder or an older boiler

System and regular boilers store hot water in a cylinder, and stored hot water needs to be kept at 60°C or above. Below that, legionella bacteria, which can cause Legionnaires' disease, can grow in the stored water. On these boilers it's easy to turn down the hot water setting by mistake instead of the heating, so we'd suggest asking a heating engineer to lower the flow temperature for you. A combi doesn't store hot water, so it doesn't carry this risk.

If you're not sure which type you have, our guide to combi and system boilers explains how to tell them apart. If your boiler was fitted before 2005, it may not be a condensing boiler at all, and lowering the flow temperature won't bring the same saving. Ask an engineer before changing it.

When to call a heating engineer

Lowering the flow temperature is a setting change, not a repair. Call a heating engineer if:

  • the radiators never get properly warm, even after turning the setting back up

  • some radiators stay cold at the bottom, which can be a sign of sludge (dirt and rust that collects inside the system)

  • the boiler starts switching on and off much more often, makes new noises or shows a fault code

  • the controls on the front don't respond, or you'd need to open the casing to reach them

On a visit as part of our heating services, we check that your thermostat and radiator valves read accurately, set the boiler's controls to suit your home and balance the radiators. Balancing means adjusting each radiator's valve so hot water reaches every room evenly, which matters more at lower flow temperatures. Controls are also tested on every boiler service, so that's a good time to ask us about your settings.

If you'd like your heating set up properly for the rest of the winter, Plumbing and Heating Surgeons can check your boiler settings, controls and radiators in one visit. Our Gas Safe registered engineers will leave your system running at a temperature that keeps your home warm without wasting gas. Book a visit through our heating services page.